Wiring Installation Residences

DEFINITION AND POSITIONING OF EQUIPMENT:
1. Service board or meter board:
 The board on which the energy meter, cut-out, neutral link are installed is called service board or meter board..
2. Main switch board or main board:
An iron clad enclosed pattern main switch is installed on the main board. The main board should be installed as near to the service board as.possible and also near to the commencement of supply. The normal height from ground level should be 1.5 metre.
3. Main Switch:
Larger standard ratings for power loads are 15, 30, 60,100,200, ampers etc. The main switches are further divided into 2 pole, 3 pole for residential purposes. The main switch also consists of fuse kit-kats on each phase wire apart from isolating links
4. Distribution board:
The supply is brought to the distribution board from the main switch. Its function is to energise various sub circuits in a systematic manner instead of bunching various wires together with main supply 'wire
5. Fuse

A fuse is a safety device to prevent overloading and short circuiting a current circuit. It consists of a short length of conducting metal which melts at certain heat and thereby breaks the circuit.
Light point:
One in small room and two in medium and large rooms.
Socket out-let 5 Amps: Ore in normal room and two in large rooms (serving drawing dinning rooms)
15 - ampere Socket: One for heating purpose and for electric press etc.
Fan Point: One in small room and two in large rooms.
Bed Room : Every bed room should be provided with switch board near the entrance to the room.
Light Points: Two (one lamp and one fluorescent tube). Fan Points: One
Socket Out-let 5 ampere: One/two i.e., one on the switch board close to door and the other on the switch board close to bed. 
Drawing Cum Dining Room: The lighting system in the drawing cum dinning room should be made decorative and the room should be well illuminated. Following electrical points are suggested :
Light Points: Two i.e. one for lamp and other for tube. If the room is extra large, then three points should be provided.

Fan Point: Two i.e. one for drawing space and other for dinning space. Socket Outlet 5 Amp.: Two i.e. one each on switch board. Socket Outlet 15 Amp: One
Kitchen :
Light Pointst Two i.e. one on ceiling for general lighting and the other near the place where cook­ing is done. i.e. close to cooking shelf. 15-Ampere Socket: One for heater etc. Exhaust Fan : One. However it depends upon individuals choice.
Bath and Latrine.
Light: One each
15 Amp Socket for Geyser in bath room.
Exhaust Fan : One. It depends upon individuals choice.
Verandah: The requirements of number of light points will depend upon the size of verandah. However, one light and one socket outlet 5 ampere and one push button for bell are suggeste